Stannah Goods & Service Lifts

The Goodsmaster Range – Specifications

Car

Constructed from mild steel sheeting; finished in a tough grey baked enamel with heavy duty vinyl covered floor.

Speed

0.20m/s

Entrances

Single hinged steel door on 1045mm wide lift cars. Double hinged steel doors on 1305mm and 1445mm wide lift cars. Finished in grey baked enamel. Goodsmaster Plus models have vision panels fitted to lift doors as standard. Collapsible concertina gates are available as an option on all standard Goodsmaster models.

Car entrance protection

A collapsible gate is fitted to the lift car entrance(s) as standard. On Goodsmaster Plus models, this is replaced with a full height light array.

Entry choice

Up to two entrances can be fitted on each floor.

Controls

Fully automatic push button control with call and despatch facilities at each landing entrance.

Goodsmaster Plus models have a cabin control panel – key switch operation with constant pressure control and emergency stop switch. Emergency stop buttons are also fitted at each landing level.

Indicators

“Lift arrival” and “lift occupied” indicators are fitted at each entrance for extra reassurance, together with an audible lift arrival buzzer.

Goodsmaster Plus models also include a load weighing device with audible overload signal.

Travel

Up to 4 stops over a total distance of 12m of travel.

Mounting

The Goodsmaster is supplied in a structure supported frame. A solid base and support at each floor is all that is needed from your building.

Motor/winding unit

Mounted on a bedplate fixed to the lift’s structure. The motor drives a high quality reduction gearbox with 2:1 traction roping. Efficient and quiet in operation.

Safety

Standard Goodsmaster models comply with the Essential Safety Requirements (ESRs) of the Supply of Machinery (Safety) Regulations 1992, also known as the Machinery Directive.
Goodsmaster Plus models carry full Notified Body approval.

Additional options include:

Intercom system positioned at each landing entrance, motor room enclosure, sheet steel cladding finished in grey baked enamel, chequer plate ramp.

Safe Maintenance Access

Please be aware that current Health & Safety Regulations, i.e. Construction Design & Management and The Provision & Use of Work Equipment specify; Access to all parts of machinery requiring maintenance must be planned to be both safe and accessible. The Goodsmaster you are planning to install requires regular maintenance. Therefore careful planning will be required to ensure safe access into the motor compartment is provided. The Goodsmaster normally requires 2 maintenance access points. The location of these points of access will depend on the landing door positions needed.

For further advice please contact us on 01264 351922.