Stannah Goods & Service Lifts
The Goodsmaster Range – Technical Data
| Technical Data | |||||||
|---|---|---|---|---|---|---|---|
| Model | Capacity | Car Dimensions (w × d × h) |
Entrance (w × h) |
Shaft (w × d) |
Pit (Ramp) Depth |
Headroom | |
| GM | (GM+) | ||||||
| 500B 750B 1000B |
500kg 750kg 1000kg |
1045 × 1235† × 2000 | 1010 × 2000 | 1650 × 1500 | 150* | 2800 | (3000) |
| 500EU 750EU 1000EU |
500kg 750kg 1000kg |
1305 × 1235† × 2000 | 1305 × 2000 | 1950 × 1500 | 150* | 2800 | (3000) |
| 750S 1000S |
750kg 1000kg |
1045 × 1735† × 2000 | 1010 × 2000 | 1650 × 2000 | 150* | 2800 | (3000) |
| 1000D 1500D |
1000kg 1500kg |
1445 × 1435† × 2000 | 1410 × 2000 | 2050 × 1700 | 150* | 3000 | (3200) |
| 1000DS 1500DS |
1000kg 1500kg |
1445 × 1735† × 2000 | 1410 × 2000 | 2050 × 2000 | 150* | 3000 | (3200) |
Key to model codes
B – Single Hinged DoorEU – Double Hinged Door
S – Single Hinged Door
D – Double Hinged Door
DS – Double Hinged Door
Notes
All dimensions are nominal and in mm
* Important Notes – Motor Housing and Pit/Ramp:
Motor Housing: It will be necessary to provide access for servicing via lockable double hinged doors for the full depth of the lift shaft. These are available from Stannah as an option.
Pit or Ramp: The Goodsmaster normally serves at floor level and would require a pit in the lowest floor. If you are unable to provide a pit, the Goodsmaster can be installed to serve at 150mm above the lowest floor and a ramp will be need to be provided by your builder.
† Car Depth: With a through car entrance arrangement, the inside car depth reduces by 25mm nominal.
N.B. Consideration must be given to protect any accessible space beneath the bottom of the lift shaft. Please contact Stannah for further information.
Datasheets giving further technical information are available from the Download Centre.