Microlift – 50kg/100kg Standard Range
A dumb waiter that is ideal for small catering premises, pubs and restaurants, offices and private homes.
The larger capacity service lift is ideal for busy catering environments, pubs, clubs and restaurants and industrial applications. Two standard lift car sizes are offered, in either dumbwaiter form with counter serving rise and fall shutters, or service lift form with floor level serving hinged doors.
Specifications
Car
Constructed in mild steel, finished in grey baked enamel with a stainless steel base and a removable stainless steel shelf. The car can also be finished in stainless steel.
Speed
0.35m/s
Entrances
High quality, smooth operation rise and fall shutters are fitted with safety locks and can be finished in either grey baked enamel (RAL 7038) or stainless steel. Hinged doors are available as an option on all models.
Car entrance protection
To meet the Essential Safety Requirements (ESRs) of the Machinery (Safety) Regulations, the lift car is supplied with car entrance protection as standard. This protects goods from falling whilst the lift is in motion.
Entry choice
For the standard range up to three entrances can be fitted on each floor. For the all other versions up to two entrances can be fitted on each floor (Bottom Drive, Low Headroom, Double Decker).
Control
Fully automatic push button control with call and despatch facilities at each entrance for ease of use.
Indicators
“Lift arrival”, “lift occupied” and “lift position” indicators are fitted at each entrance, together with an audible lift arrival buzzer.
Travel
Up to 12 stops over a total distance of 30m of travel.
Mounting
The Microlift is supplied in a structure-supported frame which is galvanised for longer life. We do not require a separate motor room or “load-bearing” lift shaft. For more information, please ask for our builder's work details.
Motor
Mounted at the top of the lift structure, the smooth, quiet motor drives a high quality reduction gearbox fitted with a traction vee-sheave. An electro-magnetic disc brake is supplied, with emergency release mechanism. The reliable controller and counter-balance drive system ensure electrical consumption is minimal.
Safety
Complies with the Essential Safety Requirements (ESRs) of the Machinery (Safety) Regulations, also known as the Machinery Directive and EN 81-3 where applicable.
Technical Data
| Model | Capacity | Car Dimensions (w × d × h) |
Entrance (w × h) |
Serving Height (variable) |
Shaft (w × d) |
Pit Depth |
Headroom |
|---|---|---|---|---|---|---|---|
| DD50 | 50kg | 510 × 320 × 800 | 320* × 770 | 800 | 725 × 520 | - | 2600 |
| 50A | 50kg | 545 × 420 × 800 | 420* × 770 | 800 | 820 × 640 | - | 2600 |
| 50B | 50kg | 520 × 520 × 800 | 420 × 770 | 800 | 800 × 800 | - | 2600 |
| 50C | 50kg | 620 × 620 × 800 | 520 × 770 | 800 | 900 × 900 | - | 2600 |
| 50C LH** | 50kg | 620 × 620 × 800 | 520 × 770 | 800 | 900 × 900 | - | 2200 |
| 100A | 100kg | 720 × 720 × 1000 | 620 × 970 | 800 | 1000 × 1000 | - | 2800 |
| WITH RISE AND FALL SHUTTERS | |||||||
| 100A | 100kg | 720 × 670 × 975 | 550 × 890 | FLOOR | 1000 × 1000 | 350* | 2000 |
| WITH HINGED DOORS | |||||||
| 100B | 100kg | 820 × 820 × 1200 | 720 × 1170 | 800 | 1100 × 1100 | - | 3000 |
| WITH RISE AND FALL SHUTTERS | |||||||
| 100B | 100kg | 820 × 770 × 1175 | 600 × 1090 | FLOOR | 1100 × 1100 | 350* | 2200 |
| WITH HINGED DOORS | |||||||
Explanatory notes
All dimensions are nominal and in mm
Some of the dimensions can be varied to suit individual requirements by modification of stock models or by special manufacture – please contact us for details.
50kg - Entrances are available on three sides (A, B & C) on all floors with the following exceptions:
Entrance position ‘B’ is not available on the DD50 model, but can be provided on the 50A model with a reduced entrance width of 320mm.
Entrances are available on two sides (A,B or C) on all floors on the 50C LH model.
100kg - Entrances are available on three sides (A,B & C) on all floors.
* For 100kg lifts with hinged door option, if floor level serving height is required then a pit will be necessary. A reduction in the pit depth is possible – please contact us for details.
** Low Headroom model.
Range of finishes